Planar Carbon Monoxide Alarm PS4200 User Manual

Planar PS-Series RS232 protocol  
(Applies to PS4200, PS4200TL, PS4250, PS4650, PS5550, PS5551, PS6500 models only)  
Table of contents  
1 Introduction ...............................................................................................................2  
2 Description.................................................................................................................2  
2.1 Hardware specification.......................................................................................2  
2.2 Communication Setting ......................................................................................2  
2.3 Command Message Reference ...........................................................................2  
3 Protocol 1 : with ID ...................................................................................................3  
3.1 Command Description........................................................................................3  
3.2 Set-Function Listing ...........................................................................................3  
3.3 Get-Function Listing...........................................................................................8  
4 Protocol 2 : without ID............................................................................................16  
4.1 Set function listing............................................................................................16  
4.2 Remote Control Pass-through mode.................................................................20  
________________________________________________________________  
V1.0  
1 / 21  
Document 020-1156-00 Rev B  
 
1. If the message is receives correctly it will send “+” (02Bh) followed by “CR” (00Dh)  
2. If the message is receives incorrectly it will send “-” (02Dh) followed by “CR” (00Dh)  
Protocol 1: with ID  
3
3.1 Command Description  
Length:  
TV ID  
Total Byte of Message excluding “CR”  
Identification for each of TV  
Command  
Type  
Identify command type,  
“s” (0x73h) : Set Command  
“g” (0x67h) : Get Command  
“r” (0x72h) : Reply Command  
“p” (0x70h) : RCU Pass-through  
“+” (0x2Bh) : Valid command Reply  
“-“ (0x2Dh) : Invalid command Reply  
Function command code: One byte ASCII code  
Command:  
Value[1~3]: Three bytes ASCII that defines the value  
0x0D  
CR  
3.2  
Set-Function Listing  
The PC can control the LCD Monitor for specific actions. The Set-Function command allows you to  
control the LCD monitor behavior in a remote sit through the RS232 port. The Set-Function packet  
format consists of 11 bytes.  
Set-Function description:  
Length:  
TV ID  
Total Byte of Message excluding “CR”  
Identification for each of TV  
If we want to set all TV settings, TV ID can use “99” to achieve, and it  
will not have Reply command on this function.  
Identify command type,  
“s” (0x73h) : Set Command  
Function command code: One byte ASCII code  
Command  
Type  
Command:  
Value[1~3]: Three bytes ASCII that defines the value  
CR 0x0D  
Set-Function format  
Send: (Command Type=”s”)  
Name Lengt  
h
ID  
Command Comman Value Value Value CR  
Type  
d
1
2
3
Byte 1 Byte  
Count  
2
Byte  
2~3  
1 Byte  
1 Byte  
1 Byte 1 Byte 1 Byte  
1
Byte  
9
Bytes  
order  
1
4
5
6
7
8
Reply: (Command Type=”+” or “-”)  
Name Lengt  
h
ID  
Command  
Type  
CR  
1
Byte 1 Byte  
2
1 Byte  
________________________________________________________________  
V1.0  
3 / 21  
Document 020-1156-00 Rev B  
 
Count  
Bytes  
order  
Byte  
2~3  
Byte  
5
1
4
Example1: Set Brightness as 76 for TV-02 and this command is valid  
Send (Hex Format)  
Name Lengt  
h
ID  
Command Comman Value Value Value CR  
Type  
0x73  
d
1
2
3
Hex  
0x38 0x30  
0x32  
0x24  
0x30  
0x37  
0x36 0x0  
D
Reply (Hex Format)  
Name Lengt  
h
ID  
Command  
Type  
CR  
Hex  
0x34 0x30  
0x32  
0x2B  
0x0  
D
Example2: Set Brightness as 176 for TV-02 and this command is NOT valid  
Send (Hex Format)  
Name Lengt  
h
ID  
Command Comman Value Value Value CR  
3
Type  
0x73  
d
1
2
Hex  
0x38 0x30  
0x32  
0x24  
0x31  
0x37  
0x36 0x0  
D
Reply (Hex Format)  
Name Lengt  
h
ID  
Command  
Type  
CR  
Hex  
0x34 0x30  
0x32  
0x2D  
0x0  
D
Example3: Set Tint as 32 for TV-03 and this command is valid  
Send (Hex Format)  
Name Lengt  
h
ID  
Command Comman Value Value Value CR  
3
Type  
0x73  
d
1
2
Hex  
0x38 0x30  
0x33  
0x27  
0x30  
0x33  
0x32 0x0  
D
Reply (Hex Format)  
Name Lengt  
h
ID  
Command  
Type  
CR  
Hex  
0x34 0x30  
0x33  
0x2B  
0x0  
D
Example4: Set Tint as 75 for TV-03 and this command is NOT valid  
Send (Hex Format)  
Name Lengt  
h
ID  
Command Comman Value Value Value CR  
d
Type  
0x73  
1
2
3
Hex  
0x38 0x30  
0x33  
0x27  
0x30  
0x37  
0x35 0x0  
D
________________________________________________________________  
V1.0  
4 / 21  
Document 020-1156-00 Rev B  
 
Reply (Hex Format)  
Name Lengt  
h
ID  
Command  
Type  
CR  
Hex  
0x34 0x30  
0x33  
0x2D  
0x0  
D
Example5: Set Brightness as 76 for all TV and this command is valid  
Send (Hex Format)  
Name Lengt  
h
ID  
Command Comman Value Value Value CR  
Type  
0x73  
d
1
2
3
Hex  
0x38 0x39  
0x39  
0x24  
0x30  
0x37  
0x36 0x0  
D
No Reply.  
Set-function table  
Set Function  
Len ID Cmd  
Command  
Type Code Code (Three ASCII  
Value Range  
Comments  
(ASCII) (Hex)  
bytes)  
Picture mode  
8
s
81  
Contrast  
Brightness  
Color  
8
8
8
8
8
8
s
s
s
s
s
s
#
$
23  
24  
82  
83  
25  
84  
Tint  
Sharpness  
Backlight  
%
Step : 20 for OSD  
display range 0~5  
8
8
s
85  
86  
DCR  
S
Color Temp  
8
s
87  
Input Resolution  
8
s
5
35  
Volume  
________________________________________________________________  
V1.0  
5 / 21  
Document 020-1156-00 Rev B  
 
8
8
s
s
6
36  
88  
Mute  
Audio Source  
8
s
89  
Only effected for  
models include  
internal speakers.  
Speaker  
8
8
8
s
s
s
1
31  
8A  
8B  
Aspect Ratio  
PIP Enable  
Full  
PIP Main Input  
8
s
8C  
PIP Sub Input  
8
8
s
s
8D  
8E  
PIP Size  
PIP Position  
8
s
000 : VGA  
Video Source  
001 : HDMI1  
003 : CVBS1  
004 : YPbPr  
005 : S-Video  
006 : DVI  
8
s
Auto adjustment  
________________________________________________________________  
V1.0  
6 / 21  
Document 020-1156-00 Rev B  
 
8
8
8
8
8
s
s
s
s
s
000 ~ 32  
000 ~ 32  
000 ~ 100  
000 ~ 100  
000: OFF  
Clock frequency  
Phase  
H.Position  
V.Position  
Ambient Light  
Sensor  
001: ON  
000: OFF  
001: ON  
000: OFF  
8
8
s
s
Blue Screen  
Auto Detect  
001: ON  
8
8
s
s
000: OFF  
Only effected for  
Touch models.  
Touch Feature  
Language  
001: On  
2
000: English  
001: French  
002: Spanish  
003: Czech  
Optional by  
different models.  
Optional by  
different models.  
004: Danish  
8
s
000: OFF  
001: ON  
Over Scan  
8
8
8
8
8
8
s
s
s
s
s
s
000 ~ 099  
000 ~ 012  
000 ~ 031  
000 ~ 023  
000 ~ 059  
000: OFF  
From 2000~2099  
RTC Year  
RTC Month  
RTC Day  
RTC Hour  
RTC Minute  
Daylight saving  
time  
001: ON  
8
8
8
8
8
s
s
s
s
s
001 ~ 010  
001 ~ 010  
001 ~ 010  
001 ~ 010  
000: OFF  
001: ON  
H Monitor  
V Monitor  
H Position  
V Position  
Frame Comp.  
8
s
000: OFF  
001: Eco  
Power save  
________________________________________________________________  
V1.0  
7 / 21  
Document 020-1156-00 Rev B  
 
002: VGA Only  
003: Standard  
8
8
s
s
3D 001 ~ 098  
Monitor ID  
47 000: OFF  
001: ON  
Image retention  
8
8
s
s
AA 000: OFF  
001: ON  
Auto adjustment  
DDC/CI  
AB 000: OFF  
001: ON  
8
8
s
s
AC  
Reset User Default  
OSD Info Box  
5B 000: OFF  
001: ON  
8
8
8
s
s
AD  
Store User Default  
Factory Reset  
Power  
7E  
!
21  
000: STBY  
001: ON  
8
s
A
41  
000 : POWER  
001 : SOURCE  
002 : MENU  
003 : UP  
Key Pad  
004 : DOWN  
005 : LEFT  
006 : RIGHT  
007 : MUTE  
000: Disable  
001: Enable  
s
B
42  
Remote Control  
002: Pass  
through  
8
8
8
s
s
s
C
E
F
43  
45  
46  
000: Disable  
001: Enable  
000: Disable  
001: Enable  
000: Disable  
001: Enable  
Key Pad function  
Menu Key function  
Power Key  
function  
3.3 Get-Function Listing  
The PC can interrogate the LCD Monitor for specific information. The Get-Function packet format  
consists of 5 bytes which is similar to the Set-Function packet structure. Note that the “Value” byte is  
always = 00.  
________________________________________________________________  
Document 020-1156-00 Rev B  
V1.0  
8 / 21  
 
Get-Function description:  
Length:  
TV ID  
Total Byte of Message excluding “CR”  
Identification for each of TV  
Command  
Type  
Command:  
Identify command type,  
“g” (0x67h) : Get Command  
Function command code: One byte ASCII code  
Value[1~3]: Three bytes ASCII that defines the value  
NOTE: to get backlight senor, thermal sensor, and ambient sensor  
need four bytes ASCII that defines the value and the length is 9.  
0x0D  
CR  
Get-Function format  
Send: (Command Type=”g”)  
Name Lengt  
h
ID  
Command Comman Value Value Value CR  
Type  
d
1
2
3
Byte 1 Byte  
Count  
2
Byte  
2~3  
1 Byte  
1 Byte  
1 Byte 1 Byte 1 Byte  
1
Byte  
9
Bytes  
order  
1
4
5
6
7
8
Reply: (Command Type=”r” or “-”)  
If the Command is valid, Command Type =”r”  
Name Lengt  
h
ID  
Command Comman Value Value Value CR  
Type  
d
1
2
3
Byte 1 Byte  
Count  
2
Byte  
2~3  
1 Byte  
1 Byte  
1 Byte 1 Byte 1 Byte  
1
Byte  
9
Bytes  
order  
1
4
5
6
7
8
If the Command is Not valid, Command Type=”-“  
Name Lengt  
h
ID  
Command  
Type  
CR  
Byte 1 Byte  
Count  
2
Byte  
2~3  
1 Byte  
1
Byte  
5
Bytes  
order  
1
4
Example1: Get Brightness from TV-05 and this command is valid.  
The Brightness value is 67.  
Send (Hex Format)  
Name Lengt  
h
ID  
Command Comman Value Value Value CR  
Type  
0x67  
d
1
2
3
Hex  
0x38 0x30  
0x35  
0x62  
0x30  
0x30  
0x30 0x0  
D
Reply(Hex Format)  
Name Lengt  
h
ID  
Command Comman Value Value Value CR  
Type  
d
1
2
3
________________________________________________________________  
V1.0  
9 / 21  
Document 020-1156-00 Rev B  
 
Hex  
0x38 0x30  
0x35  
0x72  
0x62  
0x30  
0x36  
0x37 0x0  
D
Example2: Get Brightness from TV-05 , but the Brightness command ID is error  
and it is NOT in the command table.  
Send (Hex Format)  
Name Lengt  
h
ID  
Command Comman Value Value Value CR  
Type  
0x67  
d
1
2
3
Hex  
0x38 0x30  
0x35  
0XD3  
0x30  
0x30  
0x30 0x0  
D
Reply (Hex Format)  
Name Lengt  
h
ID  
Command  
Type  
CR  
Hex  
0x34 0x30  
0x35  
0x2D  
0x0  
D
Example3: Get Tint from TV-0007 and this command is valid.  
The Tint value is 32.  
Send (Hex Format)  
Name Lengt  
h
ID  
Command Comman Value Value Value CR  
Type  
0x67  
d
1
2
3
Hex  
0x38 0x30  
0x37  
0X65  
0x30  
0x30  
0x30 0x0  
D
Reply (Hex Format)  
Name Lengt  
h
ID  
Command Comman Value Value Value CR  
Type  
0x72  
d
1
2
3
Hex  
0x38 0x30  
0x37  
0x65  
0x30  
0x33  
0x32 0x0  
D
Example4: Get Tint from TV-07 , but the Brightness command ID is error and it is NOT in the  
command table.  
Send (Hex Format)  
Name Lengt  
h
ID  
Command Comman Value Value Value CR  
2
Type  
0x67  
d
1
3
Hex  
0x38 0x30  
0x37  
0XD7  
0x30  
0x30  
0x30 0x0  
D
Reply (Hex Format)  
Name Lengt  
h
ID  
Command  
Type  
CR  
Hex  
0x34 0x30  
0x37  
0x2D  
0x0  
D
Example5 Get backlight sensor from TV-0007 and this command is valid.  
The lux value is 1786 (ASCII code).  
Send (Hex Format)  
________________________________________________________________  
Document 020-1156-00 Rev B  
V1.0  
10 / 21  
 
Name Lengt  
h
ID  
Command Comman Value Value Value Value CR  
Type  
0x67  
d
1
2
3
4
Hex  
0x39 0x30  
0x37  
0X6F  
0x30  
0x30  
0x30  
0x30 0x0  
D
Reply (Hex Format)  
Name Lengt  
h
ID  
Command Comman Value Value Value Value CR  
Type  
0x72  
d
1
2
3
3
Hex  
0x39 0x30  
0x37  
0X6F  
0x31  
0x37  
0x38  
0x36 0x0  
D
Example6 Get ambient sensor from TV-0007 and this command is valid.  
The lux value is 1568 (ASCII code).  
Send (Hex Format)  
Name Lengt  
h
ID  
Command Comman Value Value Value Value CR  
Type  
0x67  
d
1
2
3
4
Hex  
0x39 0x30  
0X70  
0x30  
0x30  
0x30  
0x30 0x0  
D
0x37  
Reply (Hex Format)  
Name Lengt  
h
ID  
Command Comman Value Value Value Value CR  
3
Type  
0x72  
d
1
2
4
Hex  
0x39 0x30  
0X70  
0x31  
0x35  
0x36  
0x38 0x0  
D
0x37  
Example7 Get thermal sensor from TV-0007 and this command is valid.  
The value is +075 degree (ASCII code). NOTE: positive degree is “+”ASCII code and negative degree  
is “-”ASCII code.  
Send (Hex Format)  
Name Lengt  
h
ID  
Command Comman Value Value Value Value CR  
Type  
0x67  
d
1
2
3
4
Hex  
0x39 0x30  
0X71  
0x30  
0x30  
0x30  
0x30 0x0  
D
0x37  
Reply (Hex Format)  
Name Lengt  
h
ID  
Command Comman Value Value Value Value CR  
4
Type  
0x72  
d
1
2
3
Hex  
0x39 0x30  
0X71  
0x2B 0x30  
0x37  
0x35 0x0  
D
0x37  
Example8 Get Running Hours from TV-0007 and this command is valid.  
The value is 21,356 hours (ASCII code).  
Send (Hex Format)  
Name Lengt  
ID  
Command Comman Value Value Value Value Value CR  
________________________________________________________________  
V1.0  
11 / 21  
Document 020-1156-00 Rev B  
 
h
Type  
0x67  
d
1
2
3
4
5
Hex  
0x3A 0x30  
0X76  
0x30  
0x30  
0x30  
0x30  
0x30 0x0  
D
0x37  
Reply (Hex Format)  
Name Lengt  
h
ID  
Command Comman Value Value Value Value Value CR  
Type  
0x72  
d
1
2
3
4
5
Hex  
0x3A 0x30  
0X76  
0x32  
0x31  
0x33  
0x35  
0x36 0x0  
D
0x37  
________________________________________________________________  
V1.0  
12 / 21  
Document 020-1156-00 Rev B  
 
PC Get-function command to LCD Monitor  
Get Function  
Len ID Cmd  
Command  
Type Code Code (Three ASCII  
Value Range  
Comments  
(ASCII) (Hex)  
bytes)  
Picture mode  
8
B1  
Contrast  
Brightness  
Color  
8
8
8
8
8
8
61  
62  
B2  
B3  
63  
B4  
Tint  
Sharpness  
Backlight  
Step : 20 for OSD  
display range 0~5  
8
8
B5  
B6  
DCR  
Color Temp  
8
B7  
Input Resolution  
8
8
66  
67  
Volume  
Mute  
8
B8  
Audio Source  
8
B9  
Only effected for  
models include  
internal speakers.  
Speaker  
________________________________________________________________  
V1.0  
13 / 21  
Document 020-1156-00 Rev B  
 
8
8
8
77  
BA  
BB  
Aspect Ratio  
PIP Enable  
Full  
PIP Main Input  
8
BC  
BD  
PIP Sub Input  
8
8
PIP Size  
000 : VGA  
001 : HDMI1  
003 : CVBS1  
004 : YPbPr  
005 : S-Video  
006 : DVI  
Video Source  
8
8
8
8
8
000 ~ 32  
Clock frequency  
Phase  
000 ~ 32  
000 ~ 100  
000 ~ 100  
000: OFF  
001: ON  
H.Position  
V.Position  
Ambient Light  
Sensor  
8
8
8
8
000: OFF  
001: ON  
Blue Screen  
Auto Detect  
Touch Feature  
Language  
000: OFF  
001: ON  
g
000: OFF  
001: ON  
Only effected for  
Touch models.  
000: English  
001: French  
002: Spanish  
________________________________________________________________  
V1.0  
14 / 21  
Document 020-1156-00 Rev B  
 
003: Czech,  
004: Danish  
Optional by  
different models.  
Optional by  
different models.  
8
000: OFF  
001: ON  
Over Scan  
8
8
8
8
8
8
000 ~ 099  
000 ~ 012  
000 ~ 031  
000 ~ 023  
000 ~ 059  
000: OFF  
001: ON  
From 2000~2099  
RTC Year  
RTC Month  
RTC Day  
RTC Hour  
RTC Minute  
Daylight saving  
time  
8
8
8
8
8
001 ~ 010  
001 ~ 010  
001 ~ 010  
001 ~ 010  
000: OFF  
001: ON  
H Monitor  
V Monitor  
H Position  
V Position  
Frame Comp.  
8
000: OFF  
001: Eco  
Power save  
002: VGA Only  
003: Standard  
8
8
75 001 ~ 098  
Monitor ID  
72 000: OFF  
001: ON  
Image retention  
8
8
DA 000: OFF  
001: ON  
Auto adjustment  
DDC/CI  
DB 000: OFF  
001: ON  
16  
DC PS5550 p.xx  
(ASCII), the return  
value will be  
different for  
FW Version  
different model  
8
8
5D 000: OFF  
001: ON  
OSD Info Box  
Power  
6C  
000: STBY  
001: ON  
________________________________________________________________  
V1.0  
15 / 21  
Document 020-1156-00 Rev B  
 
68  
000: Disable  
001: Enable  
Lock  
Remote Control  
002: Pass  
through  
000: Disable  
8
8
8
69  
73  
74  
Lock  
Lock  
Lock  
Key Pad function  
Menu Key function  
001: Enable  
000: Disable  
001: Enable  
000: Disable  
Power Key  
function  
001: Enable  
000~50  
8
8
9
9
A
g
g
g
g
g
m
n
p
q
v
6D  
6E  
70  
71  
76  
5V  
12V  
000~120  
0000 ~ 2000  
-055 ~ +125  
0 ~ 65535  
Ambient Sensor  
Thermal Sensor  
Operating Time  
Hour  
4
Protocol 2 : without ID  
Set function listing  
4.1  
The PC can control the LCD Monitor for specific actions. The Set-Function command allows you to  
control the LCD monitor behavior in a remote sit through the RS232 port. The Set-Function packet  
format consists of 5 bytes. Note that the “Value” byte is always = 00.  
Set-Function description:  
Length: Total bytes of message = 5 ASCII (35H) excluding “CR”  
Command: Function command code: One byte ASCII code  
Value[1~3]: Three bytes ASCII that defines the value  
Set-Function format:  
Name  
Byte Count 1 Byte  
Bytes order  
Length Command Value1 Value2 Value3  
CR  
1 Byte  
2
1 Byte 1 Byte 1 Byte 1 Byte  
1
3
4
5
6
All Set-Function from PC to Monitor (ASCII)  
Name  
Length Command Value1 Value2 Value3 CR  
Byte Count  
Bytes order  
5
1
1 Byte  
2
1 Byte 1 Byte 1 Byte 00D  
3
4
5
6
Example: Set Mute-ON command (ASCII)  
Name  
Length Command Value1 Value2 Value3 CR  
Byte Count  
Bytes order  
5
1
6
2
0
3
0
4
0
5
00D  
6
________________________________________________________________  
V1.0  
16 / 21  
Document 020-1156-00 Rev B  
 
Example: Set Mute-OFF command (ASCII)  
Name  
Length Command Value1 Value2 Value3 CR  
Byte Count  
Bytes order  
5
1
6
2
0
3
0
4
1
5
00D  
6
LCD Monitor will send “+” (02Bh) and “CR” bytes to PC after receiving a valid command.  
LCD Monitor will send “-” (02Dh) and “CR” bytes to PC if the command is not valid.  
Value Range: Three bytes ASCII value range  
Command Function command code in ASCII  
Code:  
set command table  
Set Function  
Len Value Range  
Comments  
Code (Three ASCII  
bytes)  
(Hex)  
Picture mode  
5
81  
Contrast  
Brightness  
Color  
5
5
5
5
5
5
23  
24  
82  
83  
25  
84  
Tint  
Sharpness  
Backlight  
Step : 20 for OSD  
display range 0~5  
5
5
85  
86  
DCR  
Color Temp  
5
87  
VGA only  
Input Resolution  
5
35  
Volume  
________________________________________________________________  
V1.0  
17 / 21  
Document 020-1156-00 Rev B  
 
5
5
36  
88  
Mute  
Audio Source  
5
89  
Only effected for  
models include  
internal speakers.  
Speaker  
5
5
5
31  
8A  
8B  
Aspect Ratio  
PIP Enable  
Full  
PIP Main Input  
5
8C  
PIP Sub Input  
5
5
8D  
8E  
PIP Size  
PIP Position  
5
000 : VGA  
Video Source  
001 : HDMI1  
003 : CVBS1  
004 : YPbPr  
005 : S-Video  
006 : DVI  
5
Auto adjustment  
________________________________________________________________  
V1.0  
18 / 21  
Document 020-1156-00 Rev B  
 
5
5
5
5
5
000 ~ 32  
Clock frequency  
Phase  
000 ~ 32  
000 ~ 100  
000 ~ 100  
000: OFF  
001: ON  
H.Position  
V.Position  
Ambient Light  
Sensor  
5
5
5
5
000: OFF  
001: ON  
Blue Screen  
Auto Detect  
Touch Feature  
Language  
000: OFF  
001: ON  
000: OFF  
001: ON  
Only effected for  
Touch models.  
000: English  
001: Franch  
002: Spanish  
003: Czech,  
Optional by  
different models.  
Optional by  
different models.  
004: Danish  
5
000: OFF  
001: ON  
Over Scan  
5
5
5
5
5
5
000 ~ 099  
000 ~ 012  
000 ~ 031  
000 ~ 023  
000 ~ 059  
000: OFF  
001: ON  
From 2000~2099  
RTC Year  
RTC Month  
RTC Day  
RTC Hour  
RTC Minute  
Daylight saving  
time  
5
5
5
5
5
001 ~ 010  
001 ~ 010  
001 ~ 010  
001 ~ 010  
000: OFF  
001: ON  
H Monitor  
V Monitor  
H Position  
V Position  
Frame Comp.  
5
000: OFF  
001: ECO  
002: VGA Only  
Power save  
________________________________________________________________  
V1.0  
19 / 21  
Document 020-1156-00 Rev B  
 
003: Standard  
3D 001 ~ 098  
5
5
Monitor ID  
Image retention  
47 000: OFF  
001: ON  
5
5
AA 000: OFF  
001: ON  
Auto adjustment  
DDC/CI  
AB 000: OFF  
001: ON  
AC  
5
5
Reset User Default  
OSD Info Box  
5B 000: OFF  
001: ON  
AD  
5
5
5
Store User Default  
Factory Reset  
Power  
7E  
21  
000: STBY  
001: ON  
5
41  
000 : POWER  
001 : SOURCE  
002 : MENU  
003 : UP  
Key Pad  
004 : DOWN  
005 : LEFT  
006 : RIGHT  
007 : MUTE  
000: Disable  
42  
Remote Control  
001: Enable  
002: Pass  
through  
5
5
5
43  
45  
46  
000: Disable  
001: Enable  
000: Disable  
001: Enable  
000: Disable  
001: Enable  
Key Pad function  
Menu Key function  
Power Key  
function  
4.2 Remote Control Pass-through mode  
When PC sets the LCD monitor to Remote Control Pass through mode, the LCD shall send a three bytes  
packet (followed by “CR”) in response to RCU button activation. Note, that in this mode the RCU shall  
have no effect on the monitor function. For example: “+Volume” will not change the volume in the  
LCD but only sends “+Volume” code to PC over the RS232 port.  
Remote Control pass-through packet format from LCD monitor to PC(ASCII)  
Name  
Length RCU-Code1 RCU-Code2  
CR  
00D  
4
Byte Count  
Bytes order  
3
1
MSB  
2
LSB  
3
Example: Remote Control pass-through when “Menu” key is pressed (2E)  
Name  
Length RCU-Code1 RCU-Code2  
CR  
Byte Count  
3
2
E
00D  
________________________________________________________________  
V1.0  
20 / 21  
Document 020-1156-00 Rev B  
 
Bytes order  
1
2
3
4
Example: Remote Control pass-through when key “DOWN” is pressed (21)  
Name  
Length RCU-Code1 RCU-Code2  
CR  
00D  
4
Byte Count  
Bytes order  
3
1
2
2
1
3
Example: Remote Control pass-through when “Power” key is pressed (0C)  
Name  
Length RCU-Code1 RCU-Code2  
CR  
00D  
4
Byte Count  
Bytes order  
3
1
0
2
C
3
RCU Key  
Support  
CODE (HEX)  
Notes  
Y
PWR  
Exit  
0C  
0F  
10  
11  
20  
21  
0D  
0A  
2E  
12  
28  
4B  
39  
38  
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
= MENU key  
Vol +  
Vol -  
UP  
DOWN  
Mute  
Enter  
= SOURCE key  
= SOURCE key  
Menu  
Information  
Input  
DVI  
VGA  
HDMI  
AV  
37  
70  
Y
YPbPr  
________________________________________________________________  
V1.0  
21 / 21  
Document 020-1156-00 Rev B  
 

Pelican DVD Recorder MD3200M User Manual
Philips Car Video System 190CW7CS User Manual
Philips DVD VCR Combo DVDR3512V 12 User Manual
Philips Stereo System FW M55 User Manual
Philips TV DVD Combo 14PT6107P User Manual
Philips VCR VR302 User Manual
Playskool Motorized Toy Car 06712 User Manual
Porter Cable Saw 4212 29550 User Manual
Poulan Lawn Mower Accessory 406288 User Manual
PYLE Audio Car Stereo System PLDTF5M User Manual